Wiring Guide
For the sake of reusability we have wired our VFD into a semi-permanent control panel using DIN terminal blocks to connect the user wiring. This control panel is designed to be fully enclosed in scenery during use.
Be sure to follow the VFD manufacturer's specifications when selecing wiring materials. You don't want to under-spec the mains or motor wiring.
Wiring Guide (For Durapulse GS20)
Terminal Number | End Point | Name |
---|---|---|
Input Side | ||
G | VFD Ground | Ground |
TERMINAL1 |
L1 | Input Power Leg 1 |
TERMINAL2 |
L2 | Input Power Leg 2 |
TERMINAL3 |
L3 | Input Power Leg 3 |
Output Side | ||
G | VFD Ground | Ground |
TERMINAL4 |
T1 | Motor Turns 1 |
TERMINAL5 |
T2 | Motor Turns 2 |
TERMINAL6 |
T3 | Motor Turns 3 |
Safety | ||
TERMINAL7 |
STO +24V | 24V Source For Safety Switches |
TERMINAL8 |
STO +24V | 24V Source For Safety Switches |
TERMINAL9 |
STO1 | Safety Input 1 |
TERMINAL10 |
STO2 | Safety Input 2 |
Control | ||
TERMINAL11 |
DCM | Digital Control Common |
TERMINAL12 |
FWD | Forward Contactor |
TERMINAL13 |
REV | Reverse Contactor |
Control Wiring
Wire | Pin | Terminal | Notes |
---|---|---|---|
Emergency Stop Button | 1 | TERMINAL9 |
STO disabled when shorted to +24VDC Source |
Emergency Stop Button | 4 | TERMINAL7 |
STO +24VDC Source |
Optional Second Emergency Stop Button | 1 | TERMINAL10 |
STO disabled when shorted to +24VDC Source |
Optional Second Emergency Stop Button | 4 | TERMINAL8 |
STO +24VDC Source |
Control Pendant | 1 | TERMINAL11 |
Voltage Sink for Digital Control |
Control Pendant | 2 | TERMINAL13 |
REVERSE when shorted to votlage sink |
Control Pendant | 3 | TERMINAL12 |
FORWARD when shorted to votlage sink |
Note: When not using the optional second emergency stop button you must have a jumper between TERMINAL8
and TERMINAL10
.