Wiring Guide

For the sake of reusability we have wired our VFD into a semi-permanent control panel using DIN terminal blocks to connect the user wiring. This control panel is designed to be fully enclosed in scenery during use.

Assembled Chassis Before Welding (photo)

Be sure to follow the VFD manufacturer's specifications when selecing wiring materials. You don't want to under-spec the mains or motor wiring.

Wiring Guide (For Durapulse GS20)

Terminal Number End Point Name
Input Side
G VFD Ground Ground
TERMINAL1 L1 Input Power Leg 1
TERMINAL2 L2 Input Power Leg 2
TERMINAL3 L3 Input Power Leg 3
Output Side
G VFD Ground Ground
TERMINAL4 T1 Motor Turns 1
TERMINAL5 T2 Motor Turns 2
TERMINAL6 T3 Motor Turns 3
Safety
TERMINAL7 STO +24V 24V Source For Safety Switches
TERMINAL8 STO +24V 24V Source For Safety Switches
TERMINAL9 STO1 Safety Input 1
TERMINAL10 STO2 Safety Input 2
Control
TERMINAL11 DCM Digital Control Common
TERMINAL12 FWD Forward Contactor
TERMINAL13 REV Reverse Contactor

Control Wiring

Wire Pin Terminal Notes
Emergency Stop Button 1 TERMINAL9 STO disabled when shorted to +24VDC Source
Emergency Stop Button 4 TERMINAL7 STO +24VDC Source
Optional Second Emergency Stop Button 1 TERMINAL10 STO disabled when shorted to +24VDC Source
Optional Second Emergency Stop Button 4 TERMINAL8 STO +24VDC Source
Control Pendant 1 TERMINAL11 Voltage Sink for Digital Control
Control Pendant 2 TERMINAL13 REVERSE when shorted to votlage sink
Control Pendant 3 TERMINAL12 FORWARD when shorted to votlage sink

Note: When not using the optional second emergency stop button you must have a jumper between TERMINAL8 and TERMINAL10.